The operations must be executed by a qualified technician.
Lubrication of the gas taps
Table for the choice of the injectors
INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Double-ring 7,00
G 30 - 28-30 mbar G 20
BURNERS G 31 - 37 mbar 20 mbar
Auxiliary (A) 1,00 0,30 50 72 (X)
Semi-rapid (SR) 1,75 0,45 65 97 (Z)
Rapid (R) 3,00 0,75 85 115 (Y)
Triple-ring 3,50 1,50 95 135 (T)
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Cat: II 2H3+
*
= Reference value