EasyManua.ls Logo

DeLonghi DTC 95 DF - Page 43

DeLonghi DTC 95 DF
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
TABLE FOR THE CHOICE OF THE INJECTORS
Cat: II 2H3+
GB
LUBRICATION OF THE GAS TAPS
If the gas tap becomes stiff, it is necessary to dismount it accurately clean it with gasoline
and spread a bit of special grease resistant to high temperatures on it.
The operations must be executed by a qualified technician.
IMPORTANT
All intervention regarding installation maintenance and conversion of the appli-
ance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Triple-ring (TR) 7,00
BURNERS
Nominal
Power
[kW]
Reduced
Power
[kW]
G 30
-
28-30 mbar
G 31 - 37 mbar
G 20
20 mbar
Ø
injector
[1/100 mm]
Ø
injector
[1/100 mm]
Auxiliary (A) 1,00 0,30 50 72 (X)
Semi-rapid (SR) 1,75 0,45 65 97 (Z)
Rapid (R) 3,00 0,75 85 115 (Y)
Triple ring (TR) 3,50 1,50 95 135 (T)