GR5 Electronic Gear Ratio (3rd Numerator) (N3) Address: 027AH, 027BH
Default: 128 Related Section: N/A
Applicable Control Mode: PT
Unit: pulse
Range: 1 ~ (2
29
-1)
Data Size: 32-bit
Display Format: Decimal
Settings:
Refer to P2-60 for explanation.
P2 - 62
GR6 Electronic Gear Ratio (4th Numerator) (N4) Address: 027CH, 027DH
Default: 128 Related Section: N/A
Applicable Control Mode: PT
Unit: pulse
Range: 1 ~ (2
29
-1)
Data Size: 32-bit
Display Format: Decimal
Settings:
Refer to P2-60 for explanation.
P2 - 63
Reserved (Do Not Use)
P2 - 64
Reserved (Do Not Use)