Chapter 8 Servo Parameters
Revision January 2011 8-105
Bit3
Bit3: Reserved. Must be set to 0.
Bit4
Bit4: ALE44 disable selection
Bit4=0: The fault, ALE44 is not disabled.
Bit4=1: The fault, ALE44 is disabled.
Bit5
Bit5: ALE41 disable selection (only available when full-close control function is
enabled)
Bit5=0: The fault, ALE41 is disabled.
Bit5=1: The fault, ALE41 is not disabled.
Bit7 Bit6
Bit6 ~ Bit7: Reserved. Must be set to 0.
P2 - 67
JSL Stable Inertia Estimating Time Address: 0286H, 0287H
Default: 1.5 Related Section: N/A
Applicable Control Mode: ALL
Unit: 0.1times
Range: 0 ~ 200.0
Data Size: 16-bit
Display Format: Decimal
Settings:
In semi-auto tuning mode, after the servo drive continuously perform the adjustment
for a period of time which is determined by P2-67, the system will consider that the
system inertia has become stable and finish the operation of system inertia estimation.