Chapter 8 Servo Parameters
Revision January 2011 8-121
P4 - 18 COF4
Current Detector Drift Adjustment (W2
phase)
Address: 0424H, 0425H
Default: Factory setting Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Display Format: Decimal
Settings:
Refer to P4-11 for explanation.
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4 - 19
TIGB IGBT NTC Calibration Address: 0426H, 0427H
Default: Factory setting Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 1 ~ 4
Data Size: 16-bit
Display Format: Decimal
Settings:
Refer to P4-11 for explanation.
When executing this auto adjustment, please ensure to cool the servo drive to 25
o
C.
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4 - 20
DOF1
Analog Monitor Output Drift Adjustment
(CH1)
Address: 0428H, 0429H
Default: Factory setting Related Section:
Applicable Control Mode: ALL Section 6.4.4
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Display Format: Decimal
Settings:
Please note that when P2-08 is set to 10, the users cannot reset this parameter.