Chapter 8 Servo Parameters
8-212 Revision January 2011
Setting value: 0x45
DI Name DI Function Description
Trigger
Method
Control
Mode
INHP
Pulse inhibit input. When the drive is in position
mode, if INHP is activated, the external pulse input
command is not valid. (Please use DI8 for INHP
signal to ensure the real-time operation of INHP
function.)
Level
Triggered
PT
NOTE
1) 11 ~ 17: Single control mode, 18 ~ 20: Dual control mode
2) When P2-10 to P2-17 is set to 0, it indicates input function is disabled.