Chapter 10 Troubleshooting
: Position deviation alarm for digital output, MC_OK
Potential Cause Checking Method Corrective Actions
After MC_OK is
activated, when the
digital output, TPOS
is Off, the digital
output, MC_OK
becomes Off.
Check if the motor position changes by
external force after the positioning is
completed.
This alarm can be disabled by the setting
of P1-48. Please refer to the descriptions
of parameter P1-48 for more detailed
explanation.
1. Turn ARST (DI signal) ON to
clear the fault.
2. Set P0-01 to 0.
10-26 Revision January 2011