Chapter 10 Troubleshooting
CANopen Communication Fault Messages
Display Fault Name Clearing Method
CANbus error
NMT Maser send “Reset node“ command to
its slave or restart the servo drive.
CANopen SDO receive
buffer overrun
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
CANopen PDO receive
buffer overrun
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
Index error occurs when
accessing CANopen PDO
object.
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
Sub-index error occurs
when accessing CANopen
PDO object.
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
Data type (size) error
occurs when accessing
CANopen PDO object.
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
Data range error occurs
when accessing CANopen
PDO object.
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
CANopen PDO object is
read-only and write-
protected.
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
CANopen PDO object
does not support PDO.
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
CANopen PDO object is
write-protected when
Servo On.
NMT Maser send “Reset node“ command to
its slave or reset the fault by sending the
control word (0x6040) through CAN
communication (the value of CANopen object
0x6040 should be reset).
Revision January 2011 10-29