Chapter 4 Parameter Settings|DD Series
4-12
05 Door Close Parameters This parameter can be set during operation.
Paramete
r
Explanation
Settings
Factory
Setting
VF
VFP
SVC
FOC
FOC
05.00
Door Close Initial Speed
0.00~120.0Hz 2.00
05.01
Door Close Distance by
Initial Speed
0~65535 (Unit: pulses number) 0
05.02
Door Close Time by Initial
Speed
0~20.0s 0
05.03
Door Close High Speed 1
0.00~120.0Hz 15.00
05.04
Door Close by Final Speed
Begins
0.0~100.0% (Door width setting in %) 10.0
05.05
Door Close Final Speed
0.00~120.0Hz 5.00
05.06
Door Close by Holding
Speed Begins
0.0~100.0% (Door width setting in %) 5.0
05.07
Door Close Holding Speed
0.00~120.0Hz 2.00
05.08
Door Close Acceleration
Time 1
0.1~3600sec 1.0
05.09
Door Close Deceleration
Time 1
0.1~3600sec 1.0
05.10
Door Close Holding Torque
Level 1
0.0~150.0% (Drive’s rated current) 50.0
05.11
Door Close Holding
Torque 1
0.0~100.0% (Drive’s rated current) 20.0
05.12
Response Time of Door
Close Holding Torque
0.01~10.00sec 0.20
05.13
Door Close High Speed 2
0.00~120.0Hz 30.00
05.14
Door Close Acceleration
Time 2
0.1~3600sec 1.0
05.15
Door Close Deceleration
Time 2
0.1~3600sec 1.0
05.16
Door Close Holding
Torque Level 2
0.0~150.0% (Ac drive’s rated current) 0.0
05.17
Door Close Time-out
Setting
0.0~180.0sec (0.0sec:Disable) 0.0
05.18
Holding Time for CD (Close
Door)Terminal
0.0~999.9sec (999.9sec is always
holding)
0.0
05.19
Door Close Acceleration
Time of S1 Curve
0.0~10.0sec 0.0
05.20
Door Close Acceleration
Time of S2 Curve
0.0~10.0sec 0.0
05.21
Door Close DC Brake
Current Level
0~100% 0
05.22
Door Close DC Brake Time
when Startup
0.0~60.0sec 0.0
05.23
Door Close DC Brake Time
when Stopping
0.0~60.0sec 0.0