Chapter 4 Parameter Settings|DD Series
4-13
Paramete
r
Explanation
Settings
Factory
Setting
VF
VFP
SVC
FOC
FOC
05.24
Door Close DC Brake
Starting Frequency
0.00~120.00Hz 0.00
05.25
Door Re-open Current
Level 1
0.0~150.0% (AC drive’s rated current) 100.0
05.26
Door Re-open Current
Level 1 for Acceleration
Area
100~200% (100% is Pr.05.25 setting) 150
05.27
Door Re-open Current
Level 1 for Low Speed Area
0.0~150.0%(Drive’s rated current) 100.0
05.28
Door Re-open Current
Level 2
0.0~150.0%(Drive’s rated current) 100.0
05.29
Door Re-open Current
Level 2 for Acceleration
Area
0.0~150.0% (Drive’s rated current) 150
05.30
Door Re-open Current
Level 2 for Low Speed Area
100~200%(100% is Pr.05.29 setting) 100.0
05.31
Door Re-open Low Speed
Boundary
1.0~99.0%(Total door width=100%;
range between 0%~Pr.05.31 is excluded
from low speed detection area)
2.0
05.32
Door Re-open Acceleration
Boundary
8.0~97.0%(Total door width =100%;
range between Pr.05.32~100% is the
acceleration area)
70.0
05.33
Door Close Error
Deceleration Time
0.1~3600sec 0.4
05.34
Door Re-open Detection
Time
0~10.0sec 0.2