Chapter 4 Parameter Settings|DD Series
4-16
Paramete
r
Explanation
Settings
Factory
Setting
VF
VFP
SVC
FOC
FOC
6: Over-current at stop (ocS) 0
7: Over voltage during acceleration
(ovA)
0
8 Over voltage during deceleration (ovd) 0
9: Over voltage during steady speed
(ovn)
0
10: Over voltage at stop (ovS) 0
11: Low voltage during acceleration
(LvA)
0
12: Low voltage during deceleration
(Lvd)
0
13: Low voltage during steady speed
(Lvn)
0
14:Low voltage at stop (LvS) 0
15:Phase loss protection (PHL) 0
16:IGBT overheat (oH1) 0
17:Reserved 0
18: IGBT overheat protection circuit
error (tH1o)
0
19~20: Reserved 0
21: 150% 1Min, AC drive overload (oL) 0
22: Motor overload (EoL1 ) 0
23~29: Reserved 0
30: Memory write-in error (cF1) 0
31: Memory read-out error (cF2) 0
32: Isum current detection error (cd0) 0
33: U-phase current detection error
(cd1)
0
34: V-phase current detection error (cd2) 0
35: W-phase current detection error
(cd3)
0
36: Clamp current detection error (Hd0) 0
37: Over-current detection error (Hd1) 0
38: Over-voltage detection error (Hd2) 0
39: Ground current detection error (Hd3) 0
40: Auto tuning error (AuE) 0
41: Reserved 0
42: PG feedback error (PGF1) 0
43: PG feedback loss (PGF2) 0
44: PG feedback stall (PGF3) 0
45: PG slip error (PGF4) 0
46~48:Reserved 0
49:External fault signal input 0
50~51: Reserved 0