OPTIONS ES300
12 / 13 DELTA ELEKTRONIKA B.V. rev. Sept. 2019
OUTPUT VOLTAGE IS HIGHER THAN SET VALUE
Check connections on TERMINAL BLOCK (on rear panel),
For normal operation there should be a link between + and S+
and between – and S– (see also
fig. 5 - 3). When remote sensing is used, check the wires of
the sensing.
5.2
BUILT IN PSC-232 for the ES 300 - series
OPTION P180
For this option the RS232 Controller PSC-232 has been built
inside the unit.
With the PSC-232 the voltage and current can easily be
programmed and read back.
Also all the status outputs can be read by the computer.
See PSC-232 manual for further details.
5.3
BUILT IN PSC-ETH for the ES 300 - series
OPTION P179
For this option the Ethernet Controller PSC-ETH has been
built inside the unit.
With the PSC-ETH the voltage and current can easily be
programmed and read back.
Also all the status outputs can be read by the computer.
See PSC-ETH manual for further details.