DC POWER SUPPLIES
DELTA ELEKTRONIKA B.V.
Vissersdijk 4, 4301 ND
Zierikzee, the Netherlands
www.DeltaPowerSupplies.com
Tel. +31 111 413656
SM3000-se ries
PROD UCT MAN UAL
Con tents:
1 - Datasheet
2 - Safety Instructions
3 - Descriptions
4 - Operating,Trouble Shooting, Calibration
5 - EC Declaration of Conformity
SM 15 - 200 D
SM 30 - 100 D
SM 45 - 70 D
SM 70 - 45 D
SM 120 - 25 D
SM 300 - 10 D
Question and Answer IconNeed help?

Do you have a question about the Delta Elektronika SM15-200D and is the answer not in the manual?

Delta Elektronika SM15-200D Specifications

General IconGeneral
Output Voltage0-15V
Output Current0-200A
Power Rating3000 W
Efficiency> 90%
Voltage Adjustment Resolution10 mV
CoolingFan
Operating Temperature0-50°C

Summary

Safety Instructions

Grounding of Mains Terminals

Safety Class 1 unit connection to electrical ground for shock hazard prevention.

Danger of Electrical Shock

Hazard of touching live contacts after disconnecting from mains.

Live Circuits

Prohibits cover removal and internal adjustments by unauthorized personnel.

Descriptions

Output Characteristics

Describes CV/CC modes, overload protection, and output ranges.

Programming Inputs

Analog voltage programming, accuracy, and shielded cable use.

Operating Temperature

Rated operating temperature and derating at higher temperatures.

Thermal Protection

Thermal switch shutdown for insufficient cooling.

Master / Slave Operation

Using units as building blocks for larger systems.

OVP (Over Voltage Protector)

Protects circuits from unwanted high output voltages.

Operating - Troubleshooting - Calibrating

Operating the Unit for the First Time

Initial setup, checks, and setting the Over Voltage Protector.

Analog Programming

Programming voltage/current via external analog voltage source.

Remote Shutdown / Over Current Trip

Operating remote shutdown and creating an over current trip circuit.

Operating and Storage Conditions

Temperature

Operating and storage temperature ranges and airflow requirements.

Trouble Shooting

General Assistance

Contacting engineers for repair assistance and RMA form.

No Output (Normal Operation)

Checks for no output condition: fuses, switches, and connections.

Programming Does Not Work OK

Troubleshooting programming errors, fuse checks, and voltage checks.

Programming Offsets

Identifying and resolving programming offsets due to earth loops.

Output Voltage Higher Than Set Value

Diagnosing and fixing high output voltage issues, checking sensing.

OVP LED On

Causes for OVP LED activation and reset procedures.

No LEDs On

Troubleshooting when no LEDs are lit on the unit.

Serious Failure Checkpoints

Systematic checks for serious unit failures like blown fuses or board issues.