1 / 30 DELTA ELEKTRONIKA B.V. rev. Jan. 2022
DELTA
ELEKTRONIKA B.V. Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com
DC POWER SUPPLIES Zierikzee, the Netherlands Tel. +31 111 413656
SM3300 - series
SM18-220
SM66-AR-110
SM100-AR-75
SM330-AR-22
SM660-AR-11
PRODUCT MANUAL
Firmware version P0157
Contents:
1 Safety Instructions
2 Sicherheitshinweise
3 Quick Start
4 General
5 Installation
6 Front Menu Operation
7 Remote Programming
8 Trouble Shooting
9 Maintenance & Calibration
10 EU Declaration of Conformity
11 UK Declaration of Conformity
Firmware Update
It is strongly recommended, first to perform a firmware update before further
operation. Download the SM3300 Quick Start Manual for instructions.
Driver & Example Software
For several applications and Interfaces there is Driver & Example Software
available on our website. See PRODUCTS\SM3300\DOWNLOADS.

Other manuals for Delta Elektronika SM18-220

Question and Answer IconNeed help?

Do you have a question about the Delta Elektronika SM18-220 and is the answer not in the manual?

Delta Elektronika SM18-220 Specifications

General IconGeneral
Output Voltage0 - 18 V
Output Current0 - 220 A
Output Power3960 W
Efficiency> 90%
Weight18 kg
Input Current16 A
ProtectionsOvervoltage, Overcurrent, Overtemperature
CoolingForced air
Input Voltage400 VAC, 3-phase

Summary

SAFETY INSTRUCTIONS

General Safety Precautions

Provides essential safety precautions for operating, servicing, and repairing the equipment.

Handling and Mounting Guidelines

Provides warnings about unit weight, potential for crushing limbs, sharp edges, and mounting restrictions.

Fan Operation and Thermal Warnings

Explains the need for proper airflow, warns about hot surfaces, blocked openings, and handling DC terminals.

AC Power Terminal Grounding

Explains the requirement for connecting the AC power terminal to safety electrical ground to minimize shock hazard.

DC Power Terminal Grounding

Covers grounding requirements for DC power terminals and sense connections, including warnings for voltages over 60VDC.

Electrical Shock Hazards

Warns about touching live contacts after disconnection and potential residual voltage from capacitors.

Mains Supply Connection

Specifies connecting to the mains supply permanently or via an industrial type plug compliant with IEC 60309.

Fuse Replacement Guidelines

States that fuses should only be replaced by authorized Delta Elektronika service personnel.

AC Input Rating Compliance

Advises not to exceed the AC input voltage and frequency ratings specified in the datasheet.

Live Circuit Precautions

Prohibits removal of unit covers and internal component replacement by unqualified personnel.

Authorized Parts Substitution

States that parts substitutions and modifications are allowed only by authorized Delta Elektronika service personnel.

Safety Cover Removal Procedures

Outlines the procedure for safely removing safety covers, including powering off and waiting for discharge.

QUICK START

Operating the Unit

Explains initial unit operation, including switching on, setting voltage/current, and understanding CV/CC modes.

GENERAL

DC Output Characteristics

Describes the unit's function as a constant voltage or constant current source and output ranges.

Overload Protection

States that the power supply is fully protected against all overload conditions, including short circuit.

Voltage and Current Limit Functions

Explains how voltage and current limits protect circuits and maintain safe output values.

Remote Sensing Functionality

Explains how remote sensing keeps load voltage constant by compensating for voltage drop.

Interlock Connector Function

Describes the interlock connector's role in turning on/off the power output and safety features.

Web Interface & Ethernet Programming

Explains the availability and functionality of the web interface and Ethernet programming.

Firmware Upgrading Procedures

Provides instructions and warnings for updating the unit's firmware.

INSTALLATION

Connecting the Unit

Details safety precautions and procedures for connecting the unit's power and other terminals.

Operating the Unit Procedures

Guides users through the initial operation of the unit, including controls and modes.

FRONT MENU OPERATION

Firmware Updating Procedures

Provides instructions on checking for and updating the unit's firmware via the web interface.

REMOTE PROGRAMMING

Web Interface Operation

Guides users on using the web interface for control, monitoring, and configuration.

Sequencer Programming

Covers downloading, uploading, and executing sequences via the web interface or Eth commands.

TROUBLE SHOOTING

Troubleshooting: No DC Output

Guides through checks for output ON status, lock mode, sense connections, and limits.

Troubleshooting: Programming Issues

Helps diagnose issues with remote programming, source settings, and command entry.

Troubleshooting: High Output Voltage

Focuses on checking sense connections and wires when the output voltage is higher than set.

Troubleshooting: Internal Error Indicator

Explains the internal error indicator and suggests checking system information or contacting support.