OPERATING - TROUBLE SHOOTING - CALIBRATING SM3000
Page 4 - 4 DELTA ELEKTRONIKA B.V. rev. February 2018
11) PAR AL LEL OP ER A TION OF FAST PRO -
GRAMMING VER SIONS:
• Mas ter / Slave op er a tion is not rec om mended.
• Nor mal par al lel op er a tion can give prob lems, each com bi na -
tion has to be tested first in com bi na tion with the load.
12) MASTER / SLAVE MIXED SERIES / PAR AL LEL
OP ER A TION
• For com plex com bi na tions as mixed se ries - par al lel al ways
use the MASTER / SLAVE SERIES ADAPTER (δ-prod uct).
• See fig. 4 - 14 for an ex am ple of how to con nect 2 units in se -
ries in par al lel with 2 units in se ries, con trolled by 1 mas ter.
• On the par al lel slave1, fully open the CV-potmeter.
• Note: A Mas ter / Slave com bi na tion can al ways be pro -
grammed, also with the IEEE488 / RS232 con trol ler
( PSC-488 mod ule / PSC-232 (both δ-prod ucts)).
fig. 4 - 13
Mas ter / Slave par al lel connections
fig. 4 - 14
Mas ter / Slave mixed se ries - par al lel con nec tions with
two MAS TER / SLAVE SE RIES ADAPT ERS