Figure 12. IC650 Comm model rear panel
6.0 Electrical Installation
The IC650 Charger has either two or three connectors on the rear panel depending on its conguration. The
Comm model with all connectors is shown in Figure 11. The Base model does not have a Comm connector,
but “Comm will still be visible on the charger because of the enclosure casting process.
DC Output Signals and Control
AC Input
6.1 AC Input
Connector Type: Standard IEC320/C14
Mating Connector: Standard IEC-60320-C13
The AC cord can be supplied by Delta-Q or standard IEC cords can be
sourced directly from a cord manufacturer or electronics distributor
(e.g. Mouser, Digi-Key).
For industrial applications where the AC cord may be exposed to
hard usage and moisture, Delta-Q recommends that the cord is UL
listed with an SJTW (or SJT) rating, 105°C (221°F), 300 V rating (or
equivalent).
To prevent the AC cord from working loose, secure it to the charger
enclosure using cable ties.
Neutral Line
Ground
Figure 13.AC Input Connector
Pin No. Wire Color Code Recommended
Wire Diameter
Description Notes
L Brown 18AWG / 1.0mm
2
AC Line Use an extension cord rated for
at least 6A at 110VAC and 3A
at 220VAC. Do not use a light-
duty indoor extension cord.
G Green / yellow AC Ground
N Blue AC Neutral
Connector Pin Conguration