13
Current transformer can detect the current of controlled conductor. It is shipped together 
with the Meter. For CT installation, please refer to the section of 4.8.8 Energy Meter 
Connections..
Current Transformer
240V / 208V grid are supported, and it can be congured via APP.
A  very  powerful  tool for  monitoring, conguration  or diagnosis. APP  is  connected  to 
inverter via BLE.
Delta Ex_BDI series can exchange with Delta cloud using gateway (Wi-Fi / Ethernet / 
Cellular) which can be installed in the AC wiring box of inverter. Also, gateway can push 
data directly to customer’s cloud or third-party cloud.
Grid
Android/iOS APP
Delta Cloud
Meter is used by the inverter to import / export consumption readings, and manage the 
battery charge / discharge accordingly for smart energy management applications, for 
example self-consumption, zero-export or TOU. Meter reports its electricity measuring 
value to inverter via RS485 following Modbus.To meet UL 1741 PCS CRD require-
ments, the meter must be installed.
For the function mode of “Self-Consumption”, “Charge Excess Solar”, “Export Only 
Mode” and “Import Only Mode”, the meter is required. For the other function modes, the 
meter is optional. For backup only application the meter is not required.
The following table summarizes wherther the meter is required or not for dierent ap-
plications:
Meter
No. Function Mode Meter Required or Not?
1 Solar Only Backup Optional
2 Self-Consumption Yes
3 Charge Excess Solar Yes
4 Charge Optional
5 Discharge TOU Optional
6 Discharge Limit Optional
7 TOU Scheduler Optional
8 Export Only Mode Yes
9 Import Only Mode Yes