1
STOP
PARE
BEFORE BEGINNING, READ ALL INSTRUCTIONS WITH PARTICULAR
ATTENTION TO SAFETY INFORMATION AND TO ENSURE YOU HAVE ALL
PARTS, TOOLS AND PROTECTIVE EQUIPMENT NEEDED TO SAFELY INSTALL
YOUR UNIT.
PLEASE DO NOT CONTACT STORE FOR REPLACEMENT PARTS
PLEASE CONTACT 1-800-964-4850 FOR ASSISTANCE
ANTES DE COMENZAR, LEA TODAS LAS INSTRUCCIONES PRESTANDO
ATENCIÓN ESPECIAL A LA INFORMACIÓN DE SEGURIDAD Y ASEGÚRESE DE
TENER TODAS LAS PIEZAS, HERRAMIENTAS Y EQUIPOS DE PROTECCIÓN
NECESARIOS PARA INSTALAR SU UNIDAD DE FORMA SEGURA.
POR FAVOR, NO CONTACTE A LA TIENDA PARA SOLICITAR PIEZAS DE
REPUESTO
POR FAVOR LLAME AL 1-800-964-4850 PARA RECIBIR ASISTENCIA
INSTALLATION GUIDE / GUÍA DE INSTALACIÓN
C500
Exposed Roller
Shower Door
5/16 inch glass (8 mm)
Rodillo expuesto
Puertas para ducha
Vidrio de 5/16 pulg. (8 mm)
CP6067583 JULY 2021
DESIGNED AND DISTRIBUTED BY LIBERTY HARDWARE MANUFACTURING CORPORATION
CAUTION:
To reduce the risk of breakage, keep corner protectors on glass while installing. Avoid contact between
shower door and metal parts and/or hard surfaces. Always ensure glass panels are placed on padded surfaces.
PRECAUCIÓN: Durante la instalación, coloque vidrio o protectores de esquinas para reducir el riesgo de romperse. Evite el
contacto entre la puerta de la ducha y las piezas metálicas y/o superficies duras. Asegúrese siempre de que los paneles de
vidrio estén colocados sobre superficies acolchadas.
NOTE:
Installation widths: 60" Tub/shower: 55-3/8"minimum – 59-3/8" maximum,
48" Shower: 43-3/8" minimum – 47-3/8" maximum.
NOTA:
Anchos de instalación: para ducha/bañera de 60" (152,40 cm): mínimo 55,375" (140,65 cm) máximo 59,375"
(150,8 cm), ducha de 48" (121,92 cm): mínimo 43,375 (110,72 cm) – máximo 47,375" (120,33 cm).
CAUTION identifies a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury and/or
property/product damage.
IMPORTANT identifies information critical to installation,
operation, or maintenance.
NOTE indicates helpful advice to make installation, operation, or
maintenance proceed well.
ADVERTENCIA identifica situaciones potencialmente peligrosas
que, de no evitarse, podrían provocar lesiones leves o
moderadas y/o daños a la propiedad/producto.
IMPORTANTE identifica información esencial para la instalación,
funcionamiento, o mantenimiento.
NOTA indica consejos útiles para una correcta instalación,
funcionamiento o mantenimiento.
Minimum Required Clearance Heights for Installation:
For Shower: 72 Inches (182.9 cm)
For Tub: 61 Inches (154.9 cm)
Minimum Required
Installation Wall Heights
for Installation:
For Shower: 69-3/8 Inches (176.2 cm)
For Tub: 61 Inches (154.9 cm)
Minimum Sill Depth
Requirements:
2-7/8" (7.1 cm)
Alturas mínimas de separación necesarias para la instalación:
Para la ducha: 72 pulgadas (182,9 cm)
Para la bañera: 61 pulgadas (154,9 cm)
Alturas mínimas de la pared necesarias para la instalación:
Para la ducha: 59,375 pulgadas (170,08 cm)
Para la bañera: 61 pulgadas (154,9 cm)
Requisitos mínimos
de profundidad del
bordillo: 2, 875"
(7,1 cm)

Questions and Answers

  • V
    Victoria KimAug 13, 2025
    How to prevent water leaks between glass panels in Delta Plumbing Product?
    • R
      Randall GuerreroAug 13, 2025
      To stop water leaks between glass panels in your Delta Plumbing Product, ensure the shower assembly is installed so the inside door panel closes on the same side as the shower head for optimal water retention. Also, check that blade seals are installed correctly, following steps 63-64.
  • J
    Joshua NewmanAug 16, 2025
    What to do if magnetic seals are not fully aligned in Delta C500 Plumbing Product?
    • N
      Natalie SanchezAug 17, 2025
      If the magnetic seals on your Delta Plumbing Product aren't fully aligned and gaps are present, adjust the height of the rollers (see steps 61-62) to close gaps at the top or bottom of the seals. With the sliding door closed, use a thin plastic shim to push the door's magnetic seal toward the wall jamb's magnetic seal where gaps remain, both inside and outside the shower.
  • P
    Patrick SmithAug 20, 2025
    How to fix water leaks under the door panel of Delta C500?
    • S
      Samuel GrossAug 20, 2025
      To resolve water leaks under the door panel of your Delta Plumbing Product, make sure water diverters are installed on the door panels with the diverter fin oriented towards the shower environment (see steps 31a, 31b and/or 39a, 39b).
  • J
    Jennifer HowardAug 25, 2025
    How to stop water from leaking under the dam strip of Delta Plumbing Product?
    • N
      Nicole GutierrezAug 25, 2025
      To prevent water leaks under the dam strip or fixed panel of your Delta Plumbing Product, ensure the dam strip and hold down brackets are properly seated against the sill. Also, evenly re-apply silicone sealant to the outside of the shower environment along all bottom surfaces, sealing the edges of the center guide and dam strip supports.
  • C
    Christopher CarrAug 28, 2025
    What to do if magnetic seals are vertically offset in Delta Plumbing Product?
    • R
      Rebecca ScottAug 28, 2025
      To fix magnetic seals that are vertically offset on your Delta Plumbing Product, first check if the glass and wall jamb are aligned. If they appear aligned but the seals resist, remove one seal, flip it vertically, and re-apply it. If the glass and wall jamb don't appear vertically aligned, the wall jamb may need to be re-installed.
  • J
    Juan MeyersAug 31, 2025
    How to stop water leaks between magnetic seals in Delta Plumbing Product?
    • A
      Adrienne RiveraAug 31, 2025
      To address water leaks between magnetic seals in your Delta Plumbing Product, ensure there is positive contact along the entire length of both magnetic seals. For seal adjustments, see steps 61-62 and the recommended actions for system alignment.
  • S
    stephanieparkerSep 4, 2025
    What to do if the sliding door panel is hard to move on Delta C500?
    • Y
      Yvonne AdkinsSep 4, 2025
      If the sliding door panel of your Delta Plumbing Product is difficult to move, check the following: 1. Ensure that the magnetic seal and blade seal on the door panel do not contact the bottom sill. 2. Check that the anti-jump assemblies are not contacting the top track; if they are, see step 44 for adjustment. 3. Ensure that the water diverter seal is not contacting the base of the center guide; if it is, press the water diverter seal firmly up against the bottom of the glass panel. 4. Clean any debris from the top track where the rollers operate. 5. Ensure that the center guide is properly connected to the bottom dam strip (see step 23).
  • B
    Brittany RyanSep 8, 2025
    Why is my Delta C500 Plumbing Product making excessive noise?
    • D
      dorseyadrienneSep 8, 2025
      If your Delta Plumbing Product is producing excess noise or vibration, carefully check all fasteners and assemblies on the inner and outer glass panels and re-install the bottom corner protection on the glass panels. Also, ensure all screws, set screws, and nuts are properly installed and hand tightened until fully secure, and that all bushings and washers are properly installed. For replacement components, call the Delta Shower Doors Customer Care Team at 1-800-964-4850.

Summary

Introduction and Preparation

Product Overview and Safety Guidelines

Model details, safety warnings, and installation precautions.

Required Tools and Parts Identification

List of necessary tools and all parts required for installation.

Installation Guide - Initial Steps and Care

Before You Start: Important Notes

Crucial pre-installation notes, warnings, and checks.

Parts Identification and Overview

Detailed identification of all parts included in the carton.

Care and Cleaning Procedures

Guidelines for proper cleaning and maintenance of the shower door.

Installation Guide - Frame and Tracks

Door Assembly and Hardware Overview

Visual guide to door assembly and hardware components.

Top Track and Bracket Installation

Detailed steps for installing the top track and wall brackets.

Dam Strip and Center Guide Installation

Procedures for installing the dam strip and center guide.

Installation Guide - Panels and Final Assembly

Inner and Outer Door Panel Installation

Step-by-step instructions for installing inner and outer glass door panels.

Roller Assembly and Side Jamb Installation

Installing roller assemblies and magnetic side jambs.

Door Adjustment and Sealing

Optional steps for fine-tuning door alignment and sealing.

Troubleshooting Common Issues

Delta C500 Specifications

General IconGeneral
BrandDelta
ModelC500
CategoryPlumbing Product
LanguageEnglish

Related product manuals