Chapter  13  Warning  CodesCP2000 
 
13-29
ID No.  Display on LCD Keypad  Warning Name  Description 
64 
 
CAN/M cycle time-out 
(PCCt) 
CANopen Master cycle time-out 
Action and Reset 
Action level 
When  the  transmitted  packet  from  CANopen  master  exceeds  the  maximum 
allowable quantity in a certain time, the PCCt warning displays.   
Action time  Immediately displays when the fault is detected   
Warning setting parameter  N/A 
Reset method 
The  warning  automatically  clears  when  changing  the  configuration  and 
re-executing the program. 
Reset condition  N/A 
Record  N/A 
Cause  Corrective Actions 
When the transmitted packet from 
CANopen master exceeds the 
maximum allowable quantity in a 
certain time 
Increase the time setting of D1090 synchronization cycle 
 
ID No.  Display on LCD Keypad  Warning Name  Description 
65 
 
CAN/M SDO over 
(PCSF) 
CANopen Master SDO overflow 
Action and Reset 
Action level 
When  the  CANopen  master  transmits  too  much  SDO  that  causes  buffer 
overflow, the PCSF warning displays 
Action time  Immediately displays when the fault is detected 
Warning setting parameter  N/A 
Reset method  Cycle the power, or stop the PLC and run the PLC again 
Reset condition  N/A 
Record  N/A 
Cause  Corrective Actions 
Internal PLC transmits too much 
SDO at once 
The PLC  program  needs  to  confirm receiving the SDO feedback data before 
sending another SDO command.