RetroSign GR1 & GR3 · Retroreflectometer 37
Example result string: (all in one line!)
4;2007/04/19 09:54:46;0;0;0;0;MES;DELTA BT;64;5552.46167N;01229.75111E;07;1;1.09;WGS84;073735;0.12;0.00;0.00;1;E0078120ADD1501D*680B
Commands that can be used on the BT connection
(Commands start with the char <#> and must end with a Carriage Return code <CR>
#DRM Do R’ measurement Tag Reader disabled
DRM:0*4D27 Instrument not calibrated
DRM:1*4E28 Executing measurement
Result string*xxxx (one line)
#DRM Do R’ measurement Tag Reader enabled
DRM:0*4D27 Instrument not calibrated
DRM:1*4E28 Executing measurement
507:0*xxxx No Reader device
507:1*xxxx Ready to read Tag
507:2*xxxx Tag Read, ready to measure
#DRM Second Do R’ measurement
DRM:1*4E28
Result string*xxxx (one line)
Result string example: (one result on each line!)
0;2007/04/19 11:17:49;0;0;0;0;MES;DELTA;77;5552.46178N;01229.75047E;09;1;0.81;WGS84;090036;0.29;0.09;0.12;3;E0078120ADD1501D*7DF1
#LHS Query Log Header Selection for dump
#LHS n Set Log Header Selection for dump
n=0 Normal Log Header (Default)
n=1 Full Log Header (TBD)
n=2 Special Log Header (TBD)
n=0 Log Header:
Index, Log record
Date and time, Measurement time
R0.2, R’ 0.2º
R0.5, R’ 0.5º
R1.0, R’ 1.0º
Status, Instrument status (4 HEX char)
Mode, Operation mode
Seq_ID, Sequence ID
ID_cnt, Number in sequence
Lat, Latitude N/S