ID
Display on LCD Keypad
Fault Name
Fault Descriptions
192
Homing deviation is
too large
(HmOE)
Home offset overflows after matching with the gear
ratio
Action and Reset
Action condition
Activates when the home offset overflows after matching with the gear ratio
Action time
Act immediately
Fault treatment parameter
N/A
Reset method
Manual reset
Reset condition
Reset immediately
Record
Yes
Cause
Corrective Actions
Home offset is set incorrectly
Modify the Home Offset setting value between ±2
31
after multiplying the gear
ratio