Chapter 13 Warning CodesC2000 Plus
13-56
ID No. Display on LCD Keypad Warning Name Description
64
CAN/M cycle time-out
(PCCt)
CANopen Master cycle time-out
Action and Reset
Action condition
When the transmitted packet from
CANopen master exceeds the maximum
allowable quantity in a certain time, the PCCt warning displays.
Action time Immediately displays when the fault is detected
Warning setting parameter N/A
Reset method
The warning automatically clears when changing the configuration and re-
executing the program.
Reset condition N/A
Record N/A
Cause Corrective Actions
When the transmitted packet from
CANopen master exceeds the
maximum allowable quantity in a
certain time
Increase the time setting of D1090 synchronization cycle