EasyManua.ls Logo

Delta VFD040C43A-21 - Page 891

Delta VFD040C43A-21
1259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 13 Warning CodesC2000 Plus
13-90
ID No. Display on LCD Keypad Warning Name Description
123
Deceleration energy
backup (dEb)
Deceleration energy backup
Action and Reset
Action condition Software detection
Action time N/A
Warning setting parameter
0: Disable
1: dEb with auto accel./decel., the output
frequency will note return after power
reply.
2: dEb with auto accel./decel., the output frequency will return after power reply.
3: dEb low-voltage control, then increase to 350V
DC
/700V
DC
and decelerate to
stop.
4: dEb high-voltage control of 350V
DC
/700V
DC
and decelerate to stop
Reset method Manual reset
Reset condition Immediately resets
Record N/A
Cause Corrective Actions
Instantaneous power off or low
voltage and unstable/ sudden
heavy load of the power that
cause the voltage drop
Check the power consumption
Unexpected power off Check the power consumption

Table of Contents

Related product manuals