Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-36
ID* Display on LCD Keypad Fault Name Fault Descriptions
30
EEPROM write error
(cF1)
Internal EEPROM cannot be programmed
Action and Reset
Action condition Firmware internal detection
Action time cF1 acts immediately when the drive detects the fault.
Fault treatment parameter N/A
Reset method Manual reset
Reset condition Reset immediately
Record Yes
Cause Corrective Actions
Internal EEPROM cannot be
programmed
Press “RESET key or reset the parameter to the default setting, if
cF1 still
occurs, return to the factory for repair.
Cycle the power, if cF1 still occurs, return to the factory for repair.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD040C43A-21 and is the answer not in the manual?

Delta VFD040C43A-21 Specifications

General IconGeneral
BrandDelta
ModelVFD040C43A-21
CategoryDC Drives
LanguageEnglish