Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-48
ID* Display on LCD Keypad Fault Name Fault Descriptions
43
PG feedback loss
(PGF2)
Pr.10-00 and Pr.10-
02 is not set in the PG control mode.
When press RUNkey, PGF2 fault occurs.
Action and Reset
Action condition Software detection
Action time Act immediately
Fault treatment parameter N/A
Reset method Manual reset
Reset condition Reset immediately
Record Yes
Cause Corrective Actions
Incorrect setting of encoder
parameter
Reset encoder parameters (Pr.10-00 and Pr.10-02)
Incorrect selection of the control
mode
Choose the correct control mode.