Chapter 10 Auto-tuning Process | VFD-ED
10-23
 Mechanical inertia reference value (%):
Load / Motor IM PM
Without load 40 10
With load 80–120 40
10-3-6 Trial Run
Test method:
1. Position the elevator near the middle floors.
2. Enter the correct values for Pr.00-14 and Pr.00-15.
3. Use the upward / downward operation of the inspection mode to execute the trial run.