Chapter 10 Auto-tuning Process | VFD-ED
10-27
Stage
Function Pr. Control Mode Description Settings Default
02-37
VF, VFPG, SVC,
FOCPG, FOCPM
Torque Check
0: Disable
1: Enable
0
DC Brake
07-30
VF, VFPG, SVC
DC Brake Current
Level at Stop
0–100%
(motor drive rated current)
0
07-04
VF, VFPG, SVC,
FOCPG, FOCPM
DC Brake
Stopping Time
0.0–60.0 sec. 0.7