Chapter 11 Summary of Parameter Settings | VFD-ED
11-9
Pr. Parameter Name Setting Range Default
VF
VFPG
SVC
FOCPG
FOCPM
31: High torque bias (according to
Pr.07-21)
32: Middle torque bias (according to
Pr.07-22)
33: Low torque bias (according to Pr.07-
23)
3437: Reserved
38: Disable writing to EEPROM function
39: Torque command direction (0 is
positive direction)
40: Enable drive function
41: Magnetic contactor detection
42: Mechanical brake 1
43: EPS function (Emergency Power
System)
44: Mechanical brake 2
4551: Direct docking mode only
53: Terminal leveling signal for direct
docking
54: Power failure signal
55: Manual emergency deceleration
56: Automatic emergency deceleration
57: Brake torque test action signal
59: AFE fault
02-09
Digital Input Response
Time
0.00130.000 sec. 0.005
02-10
Digital Input Operation
Direction
0–65535 0
02-11
Multi-function Output 1:
RA, RB, RC (Relay1)
0: No function
0
1: Operation indication
02-12
Multi-function Output 2:
MRA, MRB, MRC
(Relay2)
2: Operation speed reached
0
3: Desired frequency reached 1 (Pr.02-
25, Pr.02-26)
02-13
Multi-function Output 3:
R1A, R12C (Relay3)
4: Desired frequency reached 2 (Pr.02-
27, Pr.02-28)
0
02-14
Multi-function Output 4:
R2A, R12C (Relay4)
5: Zero speed (Frequency command) 0
02-15
Multi-function Output 5:
(MO1)
6: Zero speed with stop (Frequency
command)
0
02-16
Multi-function Output 6:
(MO2)
7: Over-torque (OT1) (Pr.06-0506-07) 0
02-17
Multi-function Output 7:
(MO3)
8: Over-torque (OT2) (Pr.06-0806-10) 0
02-18
Multi-function Output 8:
(MO4)
9: Drive ready 0

Table of Contents

Related product manuals