12 Descriptions of Parameter Settings | VFD-ED
12-02-2
Multi-function Input Command 5 (MI5)
Default: 0
Multi-function Input Command 6 (MI6)
Default: 0
Multi-function Input Command 7 (MI7)
Default: 0
Multi-function Input Command 8 (MI8) (Enable Drive terminal)
Default:40
Settings Control Mode
VF VFPG SVC FOCPG
FOCPM
0: No function
1: Multi-step speed command 1
2: Multi-step speed command 2
3: Multi-step speed command 3
4: Multi-step speed command 4
5: Reset
6: JOG command
7: Acceleration/deceleration speed inhibit
8: First, second
acceleration/deceleration time
9: Third, fourth
acceleration/deceleration time
10: EF input (Pr.07-28)
11: Reserved
12: Stop output
1314: Reserved
15: AUI1 operation speed command
16: Reserved
17: AUI2 operation speed command
18: Emergency Stop (Pr.07-28)
1923: Reserved
24: FWD JOG Command
25: REV JOG Command
26: Reserved
27: ASR1/ASR2 selection
28: Emergency stop (EF1) (motor coasts to stop)
2930: Reserved
31: High torque bias (according to Pr.07-21)
32: Middle torque bias (according to Pr.07-22)
33: Low torque bias (according to Pr.07-23)
3437: Reserved
38: Disable writing to EEPROM
39: Torque command direction (0 is positive
direction)
40: Enable drive function