12 Descriptions of Parameter Settings | VFD-ED
Accumulated Drive Power-on Time at the First Fault (min.)
Accumulated Drive Power-on Time at the Second Fault (min.)
Accumulated Drive Power-on Time at the Third Fault (min.)
Accumulated Drive Power-on Time at the Fourth Fault (min.)
Accumulated Drive Power-on Time at the Fifth Fault (min.)
Accumulated Drive Power-on Time at the Sixth Fault (min.)
Control Mode
VF VFPG SVC FOCPG Default: Read only
Settings 0–65535 min.
Accumulated Drive Power-on Time at the First Fault (day)
Accumulated Drive Power-on Time at the Second Fault (day)
Accumulated Drive Power-on Time at the Third Fault (day)
Accumulated Drive Power-on Time at the Fourth Fault (day)
Accumulated Drive Power-on Time at the Fifth Fault (day)
Accumulated Drive Power-on Time at the Sixth Fault (day)
Control Mode
VF VFPG SVC FOCPG Default: Read only
Settings 0–65535 day
Fault and Warning Action
Control Mode
VF VFPG SVC FOCPG FOCPM
Default: 0
Settings Bit 0 = 0: Display Lv fault and coast to stop
Bit 0 = 1: Display Lv warn and coast to stop
Bit 1= 0: Fan lock, fault and coast to stop
Bit 1 = 1: Fan lock, warn and continue operation
Bit 2 = 0: Software GFF protection enabled
Bit 2 = 1: Software GFF protection disabled
Voltage of Emergency Power
Control Mode
VF VFPG SVC FOCPG FOCPM
Default: 24.0/48.0
Settings 24.0–375.0 V
DC
48.0–750.0 V
DC
This parameter works with setting 43 (EPS function) for Pr.02-01–Pr.02-08 (multi-function input
commands).
Emergency Power (EPS) Mode Operation Speed
Control Mode
VF VFPG SVC FOCPG FOCPM
Default: Read only
Settings 0.00–299.00 Hz
Emergency Power (EPS) ON Operation Direction
Control Mode
VF VFPG SVC FOCPG FOCPM
Default: 0