Chapter 11 Summary of Parameter SettingsC2000-HS
11-33
07 Special Parameters
Pr. Parameter Name Setting Range Default
07-00 Software brake level 700.0–900.0 V
DC
740.0
07-01 DC brake current level 0–100% 0
07-02 DC brake time at run 0.0–60.0 sec. 0.0
07-03 DC brake time at stop 0.0–60.0 sec. 0.0
07-04 DC brake frequency at stop 0.0–1500.0 Hz 0.0
07-05 Voltage increasing gain 1–200% 100
07-06
Restart after momentary power
loss
0: Stop operation
1: Speed tracking by speed before the power loss
2: Speed tracking by minimum output frequency
0
07-07 Allowed power loss duration 0.0–20.0 sec. 2.0
07-08 Base block time 0.0–5.0 sec.
Depending
on the
model
power
07-09 Current limit of speed tracking 20–200% 100
07-10 Restart after fault action
0: Stop operation
1: Speed tracking by current speed
2: Speed tracking by minimum output frequency
0
07-11
Number of times of restart after
fault
0–10 0
07-12 Speed tracking during start-up
0: Disable
1: Speed tracking by maximum output frequency
2: Speed tracking by motor frequency at start
3: Speed tracking by minimum output frequency
0
07-13 dEb function selection
0: Disable
1: dEb with auto-acceleration / auto-deceleration, the
drive does not output the frequency after the power is
restored.
2: dEb with auto-acceleration / auto-deceleration, the
drive outputs the frequency after the power is
restored
3: dEb low-voltage control, then increase to 350V
DC
/
700V
DC
and decelerate to stop
4: dEb high-voltage control of 350V
DC
/ 700V
DC
and
decelerate to stop
0
07-14 dEb function reset time
0.0–25.0 sec.
3.0
07-15 Dwell time at acceleration 0.00–600.00 sec. 0.00
07-16 Dwell frequency at acceleration 0.0–1500.0 Hz 0.0
07-17 Dwell time at deceleration 0.00–600.00 sec. 0.00
07-18 Dwell frequency at deceleration 0.0–1500.0 Hz 0.0
07-19 Fan cooling control
0: Fan always ON
1: Fan is OFF after AC motor drive stops for one minute
2: Fan is ON when AC motor drive runs; fan is OFF
0

Table of Contents