Chapter 6. Suggestions and Error Corrections for Hybrid Servo DrivesC | VFD-VJ
6-3
Main circuit
Check Items Methods and Criterion
Maintenance
Period
Daily
Half
Year
One
Year
If there are any loose or missing screws Tighten or replace the screw
If machine or insulator is deformed, cracked,
damaged or with color change due to
overheating or ageing
Visual inspection
NOTE: Please ignore the
color change of copper
plate
If there is any dust or dirt Visual inspection
Terminals and wiring of main circuit
Check Items Methods and Criterion
Maintenance
Period
Daily
Half
Year
One
Year
If the terminal or the plate is color change or
deformation due to overheat
Visual inspection
If the insulator of wiring is damaged or color
change
Visual inspection
If there is any damage Visual inspection
DC capacity of main circuit
Check Items Methods and Criterion
Maintenance
Period
Daily
Half
Year
One
Year
If there is any leak of liquid, color change,
crack or deformation
Visual inspection
If the safety valve is not removed? If valve is
inflated?
Visual inspection
Measure static capacity when required
Resistor of main circuit
Check Items Methods and Criterion
Maintenance
Period
Daily
Half
Year
One
Year
If there is any peculiar smell or insulator
cracks due to overheat
Visual inspection, smell
If there is any disconnection Visual inspection
If connection is damaged?
Measure with multimeter with
standard specification

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD110VL43C-J and is the answer not in the manual?

Delta VFD110VL43C-J Specifications

General IconGeneral
BrandDelta
ModelVFD110VL43C-J
CategoryServo Drives
LanguageEnglish

Related product manuals