4. Description of Parameters 
 
4-11
 
Parameter 
code 
Function of the parameter  Settings 
Default 
value 
VF 
FOCPG 
FOCPM 
 
    67: Pressure feedback fault (PfbF) 
 
○ ○ ○
a 
02-07  Low voltage level 
160.0~220.0Vdc 
320.0.0~440.0Vdc 
180.0 
360.0 
○ ○ ○
a 
02-08 PTC action selection 
0: Warn and keep operation 
1: Warn and ramp to stop 
2: Warn and coast to stop   
0  ○ ○ ○
a 
02-09 PTC level 
0.0~150.0% 
0.0~150.0℃ 
50.0  ○ ○ ○
a 
02-10  PTC detection filtering time  0.00~10.00 seconds  0.20  ○ ○ ○
a 
02-11 PTC type 
0: Not assigned 
1: KTY84 
0  ○ ○ ○
a 
02-12  Motor fan activation level 
0.0~100.0% 
0.0~150.0℃ 
50.0  ○ ○ ○
a 
02-13 
Electronic thermal relay   
selection 1 
0: Inverter motor 
1: Standard motor 
2: Disable 
2  ○ ○ ○
a 
02-14 
Electronic thermal   
characteristic for motor 
30.0~600.0 seconds  60.0  ○ ○ ○
 
02-15 
Output frequency at   
malfunction 
0.00~655.35 Hz  Read only  ○ ○ ○
 
02-16 
Output voltage at   
malfunction 
0.0~6553.5 V  Read only  ○ ○ ○
 
02-17  DC voltage at malfunction  0.0~6553.5 V  Read only  ○ ○ ○
 
02-18 
Output current at   
malfunction 
0~655.35 Amps  Read only  ○ ○ ○
 
02-19 
IGBT temperature at   
malfunction 
0.0~6553.5 ℃  Read only  ○ ○ ○