4. Description of Parameters 
 
4-19
Appropriate Ki value (time)
Ki value is too low (time)
Ki value is too high (time)
 
Appropriate Kd value
Kd value is too low
Kd value is too high
 
a 
 
Base pressure 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 1.0 
 
Settings 0.0~100.0% 
  Set the minimum pressure value 100% corresponding to Parameter 00-08 
  Typically, it is necessary to maintain a certain base pressure to ensure that the oil pipe is in fully 
filled condition so as to avoid the activation delay of the cylinder when a pressure/flow command is 
activated. 
a 
 
Depressurization speed 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 25 
 
Settings 0~100% 
  Set the highest rotation speed at depressurization. The 100% value is mapped to Parameter 01-02 
(the maximum rotation speed of the motor) 
a 
 
Ramp up rate of pressure command 
a 
 
Ramp down rate of pressure command 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 100 
 
Settings 0~1000ms 
  Ramp the pressure value for the pressure command so as to reduce the vibration of the machine. 
  Set the time required for ramping the pressure from 0~the maximum pressure (00-08). 
Pressure 
command given 
to controller
Pressure 
command after 
driver processing
00-29 00-30
Time
 
a 
 
Ramp up rate of flow command 
a 
 
Ramp down rate of flow command