5. Fault Diagnostic Methods 
 
5-5
Displayed Code  Description of Failure  Solutions 
 
The output current is higher than the 
withstand current of the Hybrid 
servo drive. 
 
Check if the motor for overload.   
Increase the output capacity of the Hybrid servo drive. 
 
Motor overload
 
Change the product condition 
 
 
DC side fuse (FUSE) burns for 
models of 30HP and below.
 
Check if the fuse of the transistor module is burning. 
Check the load side for any short circuit
 
 
Memory write error.
 
 
Memory read error.
 
Press the RESET button to reset the parameters to 
factory default settings.   
If this method does not work, return to factory for 
repair.
 
 
Error of the sum of the three-phase 
output current is detected
 
 
Error U-phase current is detected.
 
 
Error V-phase current is detected.
 
 
Error W-phase current is detected.
 
After restart the power supply, if the error still exists, 
return to factory for repair. 
 
 
When the external EF terminals 
close, the Hybrid servo drive stops 
output. 
 
After clearing the cause of the error, press the 
“RESET” button. 
 
 
When the external EMG terminals 
close, the Hybrid servo drive stops 
output. 
 
After clearing the cause of the error, press the 
“RESET” button. 
 
 
The Hybrid servo drive detects 
errors from the braking transistor.
 
After press the RESET button, if the message bF still 
exists, please return to factory for repair. 
 
 
OH1 hardware circuit error
 
Return to factory for repair.
 
 
OH2 hardware circuit error
 
Return to factory for repair.
 
 
cc protection hardware circuit error
 
oc protection hardware circuit error 
 
ov protection hardware circuit error 
 
GFF protection hardware circuit 
error
 
After restart the power supply, if the error still exists, 
return to factory for repair.