Chapter 12 Descriptions of Parameter SettingsMS300
444
Setting 05: Conveyor
The following table lists the relevant conveyor setting application parameters.
Pr.
Parameter Name
Settings
00-11
Speed control mode
0 (IMVF)
00-16
Load selection
0 (Normal load)
00-20
Master frequency command source
(AUTO, REMOTE)
2 (External analog input)
00-21
Operation command source
(AUTO, REMOTE)
1 (External terminals)
01-00
Motor 1 maximum operation frequency
Default setting
01-01
Rated / base frequency of motor 1
Default setting
01-02
Rated / base voltage of motor 1
Default setting
01-03
Mid-point frequency 1 of motor 1
Default setting
01-04
Mid-point voltage 1 of motor 1
Default setting
01-05
Mid-point frequency 2 of motor 1
Default setting
01-06
Mid-point voltage 2 of motor 1
Default setting
01-07
Minimum output frequency of motor 1
Default setting
01-08
Minimum output voltage of motor 1
Default setting
01-12
Acceleration time 1
10 (sec.)
01-13
Deceleration time 1
10 (sec.)
Setting 06: Machine tool
The following table lists the relevant machine tool setting application parameters.
Pr.
Parameter Name
Settings
00-11
Speed control mode
0 (IMVF)
00-17
Carrier frequency
Default setting
00-20
Master frequency command source
(AUTO, REMOTE)
2 (External analog input)
00-21
Operation command source
(AUTO, REMOTE)
1 (External terminals)
01-00
Motor 1 maximum operation frequency
Default setting
01-01
Rated / base frequency of motor 1
Default setting
01-02
Rated / base voltage of motor 1
Default setting
01-03
Mid-point frequency 1 of motor 1
0
01-04
Mid-point voltage 1 of motor 1
0
01-05
Mid-point frequency 2 of motor 1
0
01-06
Mid-point voltage 2 of motor 1
0
01-07
Minimum output frequency of motor 1
Default setting
01-08
Minimum output voltage of motor 1
Default setting
01-12
Acceleration time 1
5 (sec.)
01-13
Deceleration time 1
5 (sec.)

Table of Contents