Chapter 12 Descriptions of Parameter SettingsMS300
445
Pr.
Parameter Name
Settings
01-24
S-curve for acceleration begin time 1
0
01-25
S-curve for acceleration arrival time 2
0
01-26
S-curve for deceleration begin time 1
0
01-27
S-curve for deceleration arrival time 2
0
02-03
Multi-function input command 3 (MI3)
1 (Multi-step speed command 1)
02-04
Multi-function input command 4 (MI4)
2 (Multi-step speed command 2)
02-13
Multi-function output 1 (RY1)
11 (Malfunction indication)
02-16
Multi-function output 2 (MO1)
1 (Indication during RUN)
02-17
Multi-function output 3 (MO2)
2 (Operation speed reached)
03-00
Analog input selection (AVI)
1 (Frequency command)
06-01
Over-voltage stall prevention
0 (Disabled)
06-03
Over-current stall prevention during
acceleration
0 (Disabled)
06-04
Over-current stall prevention during
operation
0 (Disabled)
06-05
Acceleration / deceleration time selection
for stall prevention at constant speed
0 (By current acceleration / deceleration
time)
07-01
DC brake current level
20 (%)
07-03
DC brake time at STOP
0.3 (sec.)
07-04
DC brake frequency at STOP
0 (Hz)
07-23
Automatic voltage regulation (AVR) function
1 (Disable AVR)
Setting 07: Packing
The following table lists the relevant packing setting application parameters.
Pr.
Parameter Name
Settings
00-11
Speed control mode
0 (IMVF)
00-20
Master frequency command source
(AUTO, REMOTE)
0 (Digital keypad)
00-21
Operation command source
(AUTO, REMOTE)
2 (RS-485 communication input)
02-00
Two-wire / three-wire operation control
1 (two-wire mode 1, power on for operation
control (M1: FWD / STOP, M2: REV /
STOP))
01-00
Motor 1 maximum operation frequency
Default setting
01-01
Rated / base frequency of motor 1
Default setting
01-02
Rated / base voltage of motor 1
Default setting
01-03
Mid-point frequency 1 of motor 1
Default setting
01-04
Mid-point voltage 1 of motor 1
Default setting
01-05
Mid-point frequency 2 of motor 1
Default setting
01-06
Mid-point voltage 2 of motor 1
Default setting

Table of Contents