Chapter 8 Option CardsMS300 
156 
 
8-2   CMM-PD02 – Communication card, Profibus DP 
8-2-1 Product Profile 
 
Figure 8-25  
  Wire gauge: 0.25–0.5 mm
2
 /
 
(24–20 AWG) 
  Stripping length: 7–8 mm 
  Screw torque: 2 kg-cm / (1.7 Ib-in.) / (0.2 Nm) 
1.  Screw fixing 
hole 
2.  Positioning hole 
3.  AC motor drive 
connection port 
4.  Communication 
port 
5.  Indicator   
NET1 
6.  POWER 
indicator 
7.  Ground terminal 
block 
8-2-2 Features   
1.  Supports PZD control data exchange. 
2.  Supports PKW access AC motor drive parameters. 
3.  Supports user diagnosis function. 
4.  Auto-detects baud rates; supports a maximum of 12 Mbps. 
8-2-3 Specifications   
PROFIBUS DP Connector 
Shielded twisted-pair cable 
Serial Transmission Speed 
Supported (Auto-
Detection) 
9.6 Kbps; 19.2 Kbps; 93.75 Kbps; 187.5 Kbps; 500 Kbps; 1.5 Mbps; 3 Mbps;   
6 Mbps; 12 Mbps (bits per second) 
15 V
DC
 (supplied by the AC motor drive)