Chapter 4 Description of Parameters | VFD-VJ 
 
4-14
 
Pr.    Name of Parameter    Setting 
Factory 
Setting 
VF 
FOCPG 
FOCPM 
  
66: Overpressure (ovP) 
 
○  ○  ○ 
      67: Pressure feedback fault (PfbF) 
 
○  ○  ○ 
      68: Oil pump runs reversely (Prev) 
 
 
  
69: Oil shortage (noil) 
 
 
   70: Reserved 
 
 
      71: Over current at Braking chopper (ocbs) 
 
 
  
72: Braking resistor is open-circuit (bro)   
 
 
  
73: Resistance of braking resistor is too small 
(brF) 
 
 
      74: Braking chopper overheated (oH4) 
 
 
  
75: Error occurred on Brake chopper’s 
thermal protection line (tH4o)   
 
 
   76~81: Reserved 
 
 
      82: Output Phase Loss on Phase U (oPL1)   
 
 
  
83: Output Phase Loss on Phase V (oPL2)   
 
 
      84: Output Phase Loss on Phase W (oPL3)   
 
 
      85, 86, 88~100: Reserved 
 
 
  
87: Hybrid servo drive overloading while 
running at low frequency (oL3) 
 
 
  
101: Software error 1 occurred on CANopen   
(CGdE) 
 
 
  
102: Software error 2 occurred on CANopen 
(CHbE) 
 
 
  
103: Reserved 
 
 
  
104: Hardware error occurred on CANopen 
(CbFE)  
 
 
  
105: Index setting error occurred on 
CANopen (CIdE)   
 
 
  
106: Slave # setting error occurred on 
CANopen (CAdE)   
 
 
      107: CANopen index is out of range (CFrE) 
 
 
 
02-07  Low voltage level 
160.0~220.0V
DC
 
320.0~440.0V
DC
 
180.0 
360.0 
○  ○  ○ 
 
02-08 
PTC action selection 
0: Warn and keep operation 
1: Warn and ramp to stop 
2: Warn and coast to stop   
1 
○  ○  ○ 
 
02-09 PTC level  0.0~150.0°C  
VJ-A: 120°C; 
VJ-C : 140°C   
○  ○  ○ 
 
02-10 Reserved