Chapter 4 Description of Parameters | VFD-VJ 
 
4-22
 
 
5: Display the three-phase U, V, W output power angle (n)   
(unit: deg) 
U
 
 
 
6: Display the output power in kW (P) 
U
 
 
 
7: Display the actual motor speed in rpm estimated by the motor 
drive or encoder’s feedback. 
(r 00: forward speed; - 00: negative speed) (unit: rpm) 
U
 
U
 
 
 
8: Display the estimated output torque N-m (t 0.0: positive torque; - 
0.0: negative torque) (unit: %) 
U
 
U
 
 
 
9: Display the PG feedback (G) (unit: PLS) 
U
 
 
 
10: Reserved 
 
 
 
11: Display the signal value of the analog input terminal PS with 
0~10V mapped to 0~100% (unit: %) 
U
 
 
 
12: Display the signal value of the analog input terminal PI with 
0~10V mapped to 0~100% (unit: %) 
U
 
 
 
13: Display the signal value of the analog input terminal AUI with 
-10~10V mapped to 0~100% (unit: %) 
U
 
 
 
14: Display temperature of the power module IGBT in °C (t.) 
U
 
 
 
15: Display temperature of the power capacitor °C 
U
 
 
 
16: The status of digital input (ON/OFF) 
U
 
 
 
17: The status of digital output (ON/OFF) 
U
 
 
 
18: Reserved 
U
 
 
 
19: The corresponding CPU pin status of the digital input 
U
 
 
20: The corresponding CPU pin status of the digital output 
U
 
 
21~24: Reserved 
 
 
 
25: Display the signal value of the analog input terminal QI with 
0~10V mapped to 0~100% (unit: %) 
U
 
 
 
26: Display the actual pressure value (unit: Bar) 
U
 
 
 
27: Display the kWh value (unit: kWh) 
U
 
 
 
28: Display the motor temperature in °C (currently only support 
KTY84) 
U
 
 
 
29: Over load rate of hybrid servo drive, get overloaded at 100% 
(d.) (unit: %)     
U
 
 
 
30: Over load rate of motor with last digit A of HES, get EOL1 at 
100% (M.) (unit: %) 
U
 
 
 
31: Display current at braking (A.) (unit: A) 
32: Display temperature of the braking chopper (4.) (unit: ºC) 
33: Reserved 
34: torque constant KT (unit: K) 
U
 
U
 
 
U
 
 
 
37: Reserved 
 
 
 
38: Reserved 
 
 
 
39: Reserved 
 
 
 
41: # of times to switch on/off of the soft start relays (L) (%) 
 
  This parameter defines the contents to be displayed in the U page of the digital keypad KPVJ-LE02 (as 
shown in the figure). 
 
 
Reserved