Chapter 12 Description of Parameter SettingsCP2000 
 
12.1-05-5 
 
   
 
 
Accumulated Watt-hour for a Motor (W-hour) 
 
 
          Default: 0.0 
    Settings  Read only 
 
 
Accumulated Watt-hour for a Motor in Low Word (kW-hour) 
 
 
          Default: 0.0 
  Settings  Read only 
 
 
Accumulated Watt-hour for a Motor in High Word (MW-hour) 
 
 
          Default: 0 
  Settings  Read only 
 Pr.05-28–05-30 record the amount of power consumed by the motors. The accumulation begins 
when  the  drive  is  activated  and  the  record  is  saved  when  the  drive  stops  or  turns  OFF.  The 
amount of consumed watts continues to accumulate when the drive is activated again. To clear 
the accumulation, set Pr.00-02 as 5 to return the accumulation record to 0. 
 The accumulated total watts of the motor per hour = Pr. 05-30 x 1000000 + Pr. 05-29 x 1000 + Pr. 
05-28 Wh