PROCEDURE AFTER REPLACING THE PCB. PROCEDURE AFTER REPLACING THE U-COM, ETC.
The rmware of U4 (EN25QH16B-104HIP2A) in the MAIN PCB differs depending on the region.
Be sure to follow the instructions in "FIRMWARE UPDATE PROCEDURE" to update to the latest rmware
after changing a circuit board.
The procedure after replacing the u-COM (microprocessor), ash ROM, etc. is as follows.
PCB Name Ref. No. Description
Procedure
after Re-
placement
Remark
MAIN U4 EN25QH16B-104HIP2A 16Mb B SOFTWARE : DSP
MAIN U10 STM32F030R8T6 B SOFTWARE : Main
Procedure after Replacement
A : The software has been written. The software is not written at the time of replacement.
B : The software has been written. The software may need to be rewritten by version updates. Check the
version.
C : The software has not been written. The software needs to be written after replacement.
See "FIRMWARE UPDATE PROCEDURE" for information on writing the software.
D : The software has been written. Be sure to rewrite with the latest software for your service region.
See "FIRMWARE UPDATE PROCEDURE" for information on rewriting the software.