EasyManua.ls Logo

Denon PMA-1600NE - Page 45

Denon PMA-1600NE
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Check that the voltage of PROT2
is active. [Q144 : collector]
Malfunction of [U8601, 8602].
Malfunction of [U414].
Malfunction of [U412].
Malfunction of [D8601].
Malfunction of [U201].
・Detection of the DC offset
・Thermal detection
・Over current
Damage to power amplier
Damage to power supply circuit
Check that voltage is supplied
to the [C407, C408]
Check that voltage is supplied
to the [U414] output (+5V)
Check that voltage is supplied
to the [U412] output (+5V)
Check that voltage is supplied
to [N1011 : 1, 2pin]
Check that voltage is supplied
to [C207]
Check the input level, speaker
connector and speaker resis-
tance value
Check that the voltage of VOLT-
AGE_PROT is active. [Q120 :
Collector]
Check that voltage is supplied
to [U102 : 48pin]. (ANA_MODE)
Malfunction of [D8602-8605].
Check that voltage is supplied
to [U201 : 5pin]
Check that voltage is supplied to
[N450 : 1pin] and [N450 : 4pin]
Hi Lo Hi Lo
Active Active
NG
NG
NG
NG
NG
Hi
Hi
Malfunction of [U8502, D8513 -
8520].
Malfunction of [Q101, 104].
Check that voltage is supplied
to [N311 : 1pin] (U8503 output)
Check that voltage is supplied
to the [Q104 : collector]
NG
NG
YES
YES
YES
YES
YES
YES
YES
YES Hi
NG
NG
YES
YES
YES
45
Caution in
servicing
Electrical Mechanical Repair Information Updating

Other manuals for Denon PMA-1600NE

Related product manuals