EasyManua.ls Logo

Dettson Chinook C120-M-V - User Manual

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
2016-09-19 X40225 Rev.O
IMPORTANT: The furnace must be installed with the Modulating Touch-
Screen Thermostat R02P030 (#1F95M). If the furnace is to be installed with the modulating cooling option, use
the Communicating Thermostat R02P029 (#1F991292).
ATTENTION: Do not tamper with the unit or its controls. Call a qualified service technician.
INSTALLER / SERVICE TECHNICIAN: Use the information in this manual for the installation / servicing of the furnace and
keep the document near the unit for future reference.
Gas furnaces manufactured on or after May 1, 2017 are not permitted to be used in Canada for heating of buildings or
structures under construction.
These instructions must be read and understood completely before attempting installation.
HOMEOWNER: PLEASE Keep this manual near the furnace for future reference.
Manufactured by:
Industries Dettson Inc.
Sherbrooke (Québec) Canada
www.dettson.ca

Table of Contents

Other manuals for Dettson Chinook C120-M-V

Question and Answer IconNeed help?

Do you have a question about the Dettson Chinook C120-M-V and is the answer not in the manual?

Summary

Installation Guide and Owners Manual

Required notice for Massachusetts installations

1- SAFETY REGULATION

Safety Labeling and Warning Signs

Explains DANGER, WARNING, and NOTE symbols used in the manual.

2- INTRODUCTION

Codes and Standards

Lists national and local codes required for installation.

Location Guidelines

Guidelines for selecting a suitable and safe installation location.

4- INSTALLATION

5- DUCT INSTALLATION

6- GAS PIPING

General Gas Piping Requirements

Requirements for gas piping installation according to national and local codes.

7- ELECTRICAL CONNECTIONS

120 V Wiring

Electrical connection requirements for the 120V power supply.

Thermostat Selection and Wiring

Information on selecting and connecting thermostats for the furnace system.

8- VENTING AND COMBUSTION AIR PIPING

Vent Termination Installation

Procedures for properly installing vent terminations on roofs or sidewalls.

9- START UP, ADJUSTMENT AND SAFETY CHECK

Starting the Furnace

Step-by-step instructions for starting the furnace and its lighting sequence.

Sequence of Operation

Detailed steps of the furnace's heating cycle initiation and operation.

10- THERMOSTAT

Memory Card and Shared Data

Rules for furnace shared data, memory card usage, and arbitration.

Replacing the Furnace Control

Procedures and warnings for replacing the furnace control board and memory card.

Dipswitch Settings

Configuration of dipswitch settings for airflow adjustments and test modes.

11- USERS INFORMATION MANUAL

Furnace Maintenance

Routine maintenance tasks and recommendations for furnace longevity and performance.

Safety Switches and Fault Codes

Details on safety switches, fault code buffer, and active fault codes.

Dettson Chinook C120-M-V Specifications

General IconGeneral
BrandDettson
ModelChinook C120-M-V
CategoryFurnace
LanguageEnglish

Related product manuals