2015-07-09 X40225 rev.L
IMPORTANT: The furnace must be installed with the Modulating Touch-Screen Thermostat R02P030 (#1F95M). If
the furnace is to be installed with the modulating cooling option, use the Communicating Thermostat R02P029
(#1F991292)
ATTENTION: Do not tamper with the unit or its controls. Call a qualified service technician.
INSTALLER / SERVICE TECHNICIAN: Use the information in this manual for the installation / servicing of the furnace and
keep the document near the unit for future reference.
These instructions must be read and understood completely before attempting installation.
HOMEOWNER: PLEASE Keep this manual near the furnace for future reference.
Manufactured by:
Industries Dettson Inc.
Sherbrooke (Québec) Canada
www.dettson.ca

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Dettson Chinook C60-M-S and is the answer not in the manual?

Summary

1- Safety Regulation

1.1- Safety Labeling and Warning Signs

Explains the meaning of DANGER, WARNING, and CAUTION labels.

1.2- Important Information

Emphasizes homeowner responsibility for qualified technician installation and service.

1.3- Detection Systems

Recommends carbon monoxide and smoke detectors for safety.

2- Introduction

2.1- Codes and Standards

Lists national and local codes for installation, including safety, electrical, and gas piping.

2.3- Location

General requirements and considerations for furnace placement.

3- Combustion Air and Ventilation

3.1.1- Direct Vent (2 Pipe Applications)

Requirements for direct vent system air supply.

3.1.2- Non Direct Vent (1 Pipe) Applications

Ensuring adequate combustion air for non-direct vent systems.

3.1.3- Ventilated Combustion Air Applications

Requirements for ventilated combustion air systems.

3.2- Connecting to Furnace

3.2.1- Combustion Air Piping

Guidelines for installing combustion air piping.

3.2.2- Exhaust Vent Piping

Guidelines for installing exhaust vent piping.

4- Installation

4.1- Upflow Orientation

Instructions for installing the furnace in the upflow position.

4.2- Down Flow Orientation

Steps for installing the furnace in the downflow position.

4.3- Horizontal Right Orientation

Instructions for installing the furnace in the horizontal right orientation.

4.4- Horizontal Left Orientation

Instructions for installing the furnace in the horizontal left orientation.

5- Duct Installation

5.1- Return Air Connections

Instructions for connecting return air ducts.

5.1.1- Bottom Return Air Inlet

Connecting the return air duct to the bottom inlet.

5.1.2- Side Return Air Inlet

Connecting the return air duct to the side inlet.

5.3- Supply Air Ducts

Guidelines for connecting supply air ducts.

5.4- General Requirements

General requirements for duct system design and sizing.

6- Gas Piping

7- Electrical Connections

7.1- 120 V Wiring

Requirements for connecting 120V power supply.

7.2- 24 V Wiring

Instructions for making 24V thermostat connections.

8- Venting

9- Start Up, Adjustment and Safety Check

10- Thermostat

Dettson Chinook C60-M-S Specifications

General IconGeneral
ModelChinook C60-M-S
TypeGas Furnace
Efficiency95% AFUE
Blower TypeVariable Speed
ConfigurationUpflow/Horizontal
Motor TypeECM
StagesModulating
Heating Capacity60, 000 BTU/h
Fuel TypeNatural Gas
Warranty10-year parts, limited lifetime heat exchanger