2016-09-19 X40225 Rev.O
IMPORTANT: The furnace must be installed with the Modulating Touch-
Screen Thermostat R02P030 (#1F95M). If the furnace is to be installed with the modulating cooling option, use
the Communicating Thermostat R02P029 (#1F991292).
ATTENTION: Do not tamper with the unit or its controls. Call a qualified service technician.
INSTALLER / SERVICE TECHNICIAN: Use the information in this manual for the installation / servicing of the furnace and
keep the document near the unit for future reference.
Gas furnaces manufactured on or after May 1, 2017 are not permitted to be used in Canada for heating of buildings or
structures under construction.
These instructions must be read and understood completely before attempting installation.
HOMEOWNER: PLEASE Keep this manual near the furnace for future reference.
Manufactured by:
Industries Dettson Inc.
Sherbrooke (Québec) Canada
www.dettson.ca

Table of Contents

Other manuals for Dettson Chinook C45-M-V

Question and Answer IconNeed help?

Do you have a question about the Dettson Chinook C45-M-V and is the answer not in the manual?

Summary

Safety Regulation

Safety labeling and warning signs

Explains DANGER and WARNING labels for hazard severity.

Important information

Emphasizes consequences of non-compliance and homeowner responsibility.

Detection systems

Recommends CO and smoke detectors for safety and furnace safety devices.

Installation

Duct Installation

General requirements

Standards and guidelines for designing and installing duct systems.

Gas Piping

General

Requirements for gas piping installation according to codes.

Gas valve and propane conversion kit

Instructions for converting the furnace from natural to propane gas.

Electrical Connections

120 V wiring

Requirements for connecting the 120V power supply to the furnace.

Thermostats

Information on selecting and wiring compatible thermostats.

Venting and Combustion Air Piping

Installing the vent termination

Procedures for installing concentric, two-pipe, and sidewall vent terminations.

Start Up, Adjustment and Safety Check

To start the furnace

Steps for initiating furnace operation and lighting procedures.

Unit operation hazard

Warnings about hazards during furnace operation and safety controls.

Setup switches

How to configure furnace settings using dipswitches.

Thermostat

Users Information Manual

Operating and Lighting Your Furnace

Basic operation, lighting procedures, and safety checks for the furnace.

Routine Furnace Maintenance

Routine maintenance steps for efficient and safe furnace operation.

Fault Code Resolution

Procedures for clearing faults and understanding active fault codes.

Dettson Chinook C45-M-V Specifications

General IconGeneral
ModelChinook C45-M-V
TypeGas Furnace
Heating Capacity45, 000 BTU/h
Fuel TypeNatural Gas or Propane
Efficiency95% AFUE
Blower TypeVariable Speed
Motor TypeECM
Blower MotorVariable Speed ECM
Ignition TypeHot Surface Ignition
Vent TypeDirect Vent
Warranty10-Year Limited Warranty