Please also note the following:
The installation of the thermostat must be done by an
authorized and qualified installer according to local
regulations.
The thermostat must be connected to a power supply
via an all-pole disconnection switch.
The sensor is to be considered as live voltage. Have
this in mind if the sensor must be extended.
Always connect the thermostat to continuous power
supply.
Do not expose the thermostat to moisture, water, dust,
and excessive heat.
2 Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable height on the
wall (typically 80-170 cm.).
In wet rooms, place the thermostat according to
local regulation on IP classes.
DEVIreg™ 132
6 Installation Guide