ENGLISH
10
locating any accessory, please contact
Industrial
Tool Co., 701East Joppa Road, Towson, MD 21286, call
1-800-4-
(1-800-433-9258) or visit our website:
www.dewalt.com.
Repairs
The charger and battery pack are notserviceable.
WARNING: To assure product SAFETY and
RELIABILITY, repairs, maintenance and adjustment
(including brush inspection and replacement, when
applicable) should be performed by a
factory
service center or a
authorized service center.
Always use identical replacementparts.
Register Online
Thank you for your purchase. Register your product nowfor:
• WARRANTY SERVICE: Registering your product will
help you obtain more efficient warranty service in case
there is a problem with yourproduct.
• CONFIRMATION OF OWNERSHIP: In case of
an insurance loss, such as fire, flood or theft, your
registration of ownership will serve as your proof
ofpurchase.
• FOR YOUR SAFETY: Registering your product will
allow us to contact you in the unlikely event a safety
notification is required under the Federal Consumer
SafetyAct.
Register online at www.dewalt.com/register.
Three Year Limited Warranty
will repair, without charge, any defects due to
faulty materials or workmanship for three years from the
date of purchase. This warranty does not cover part failure
due to normal wear or tool abuse. For further detail of
warranty coverage and warranty repair information, visit
www.dewalt.com or call 1-800-4-
(1-800-433-9258).
This warranty does not apply to accessories or damage
caused where repairs have been made or attempted by
others. This warranty gives you specific legal rights and
you may have other rights which vary in certain states
orprovinces.
In addition to the warranty,
tools are covered
byour:
1 YEAR FREE SERVICE
will maintain the tool and replace worn parts
caused by normal use, for free, any time during the first year
afterpurchase.
2 YEARS FREE SERVICE ON DEWALT BATTERY PACKS
DC9071, DC9091, DC9096, DC9182, DC9280, DC9360, DCB120,
DCB127, DCB201, DCB203, DCB203BT, DCB207, DCB361
3 YEARS FREE SERVICE ON DEWALT BATTERY PACKS
DCB200, DCB204, DCB204BT, DCB205, DCB606
NOTE: Battery warranty voided if the battery pack is
tampered with in any way.
is not responsible
for any injury caused by tampering and may prosecute
warranty fraud to the fullest extent permitted bylaw.
90 DAY MONEY BACK GUARANTEE
If you are not completely satisfied with the performance of
your
Power Tool, Laser, or Nailer for any reason, you
can return it within 90 days from the date of purchase with
a receipt for a full refund – no questionsasked.
LATIN AMERICA: This warranty does not apply to products
sold in Latin America. For products sold in Latin America,
see country specific warranty information contained in
the packaging, call the local company or see website for
warrantyinformation.
FREE WARNING LABEL REPLACEMENT: If your warning
labels become illegible or are missing, call 1-800-4-
(1-800-433-9258) for a freereplacement.
Troubleshooting Guide
SYMPTOM CAUSE REMEDY
Motor does not start Trigger not depressed
Discharged battery
Speed or Dose setting too low
Battery pack not fullyinserted.
Cartridge or sausage fully dispensed
(dispenser shuts off automatically)
• Presstrigger.
• Use charger to rechargebattery.
• Increase speed setting
• Increase dose setting
• Remove and reinstall batterypack.
• Remove and replacecartridge.
Motor stops suddenly while running Dose completed
Battery pack not fullyinserted.
Cartridge fully dispensed (dispenser
shuts off automatically)
• Release trigger, increase “dose”,
presstrigger.
• Remove and reinstall batterypack.
• Remove and replacecartridge.
Motor stops gradually or slowsdown. Discharged battery
Speed setting too low
• Use charger to rechargebattery.
• Increase speed setting
Motor runs, but adhesive is not
beingdispensed.
Clutch open
Cartridge tip not removed
Adhesive toocold
Cured adhesive clogging mixing tube
Cartridge failure (blow by)
• Closeclutch.
• Removetip.
• Warm theadhesive.
• Replace mixing nozzle
(mixingtube).
• Remove cartridge. Clean pistons
and teeth. Install newcartridge.
Adhesive is dispensed very slowly Discharged Battery
Speed setting too low
Adhesive toocold
Cured adhesive clogging mixing tube
Cartridge failure (blow by)
• Use charger to rechargebattery.
• Increase speed setting
• Warm theadhesive.
• Replace mixing nozzle
(mixingtube).
• Remove cartridge. Clean pistons
and teeth. Install newcartridge.
Dispensed adhesive is not
uniformlymixed.
Adhesive toocold.
Cured adhesive in mixing nozzle
Cartridge failure (blow by)
• Warm theadhesive.
• Replace mixing nozzle
(mixingtube).
• Remove cartridge. Clean pistons
and teeth. Install newcartridge.
Rack handle is difficult to push orpull. Clutch closed
Adhesive built up on rack teeth
Racks are bent or dammaged
• Open clutch
• Remove cartridge. Clean pistons
and teeth. Install newcartridge.
• Have tool repaired at an
authorized service center