MALFUNCTION TABLE EN
DiBO 27
7 Burner
Check if the burner opening is clear of pollution. Check pipes and connections
on leaks and external damages. Replace the filter if necessary.
Ignition transformer from the burner:
It is important that on the ignition transformer a load is connected. The
switching on of the ignition transformer without the ignition pins are connected,
are not permitted. We recommend during maintenance activities certainly
checking the connections of the ignition cables and for the case the burner
would not work, certainly don’t run the burner.
8 General control of the tanks
Check all tanks on external damages and leaks.
Check at filling of the water tank if the float system works properly.
Malfunction table
At a possible malfunction one can consult the table mentioned below and if you
obtain on this basis no solution, we advise to contact a DiBO- technician and/or
a recognized DiBO- representative.
STORING OORZAAK OPLOSSING
Machine does not start
Electrical supply not connected
Net fuse defect
Main switch on “0”
Rest malfunctions
Connect the electrical supply
Check net fuse
Put main switch on “1”
Consult an expert
No water pressure
Few water supply
Filter blocked
Repair water supply
Clean/replace filter cartridge
Instable and to weak pressure
Air in water supply (leaks in water
supply)
Nozzle or lance blocked or worn-
out.
Pressure regulator defect
Rest malfunctions
Put machine completely without
power! Repair leaks in supply.
Clean or replace
Consult an expert
Consult an expert
Water in product tank Non return valve in filter defect Replace suction filter
No additions of products
Suction pipe
Suction filter stued-up
Product tank empty
Spray pressure to high
Repair suction pipe
Clean suction filter
Refill or replace tank
Lower spray pressure
No hot water
Burner switch not on position “1” or
warm water button not switched
on.
No fuel present in the tank
Temperature sensor defective
Rest of malfunctions
Put main switch on position “1” or
check display if the warm water
button is pushed.
Fill the tank, clean or replace the
fuel filter
Consult an expert
Consult an expert
Aerator does not turn
Net fuse defect
Burner switch not on position “1” or
warm water button not switched
on.
Electrical motor defective
Check net fuse
Put burner switch on position “1”
or check display if the warm water
button is pushed.
Consult an expert
HP pump pulse
Leak or congestion in supply
conduit
To much air present
Clean/replace/repair
De-aeration of cleaner
Hot water temperature is not reached
Temperature too low or working
pressure to high
Higher temperature control +
reduce work pressure