Troubleshooting
5.3.10
5.3.10 Note jam in loopback transport of chest transport
1. Open the middle platten of the chest transport (see Section4.1.9).
Figure5-3: RM4V middle platten of chest horizontal transport
- removing notes from transport area
2. Remove notes from loopback transport (1) of
the chest horizontal transport. Loopback
transport should only be opened to a maxi-
mum 30° angle
3. Close the middle platten of the chest transport (see Section4.1.9).
5-14 Copyright 2018 Diebold Nixdorf
01750308109 A